Quaternion Pathfinder · PF-002-MECHANISM-HYPOTHESES-V1 research slice
Virtual lab - simulated experiment
PF-002 virtual lab: what new physics could change recoil, and how would it fail?
For three hypothetical mechanisms beyond ordinary radiation recoil, what would each predict at the retained source, what else must the same equations change, and which ordinary effects could mimic each one?
Reviewed research publication. This is not a physical measurement or a canonical technology-acceptance result.
In plain English
Understanding this experiment
What is being measured?
Three proposed mechanisms were written as equations and compared with ordinary recoil at one hypothetical optical source. One makes a force and a phase depend on the order of control steps. One makes emission depend on where the light will end up. One turns crossed beams into hidden quanta. Each was calculated, not observed. No apparatus exists, and none of these mechanisms has been seen.
Why does it matter?
Earlier slices asked how well a force could be read. That cannot say what new physics would look like, or how to rule it out. A serious hypothesis must state its equations, where its momentum goes, what else it changes, and what would prove it wrong. Finding the exact ordinary effect that could mimic each one is part of the result.
How does the title relate?
This PF-002 slice asks what new mechanisms would predict, and how each would fail. It is a bridge to questions the roadmap calls PF-003. It tests equations, not physics, and it establishes no new law.
Setup, objective and goal
How the experiment works
Objective
Write three materially different hypothetical mechanisms as explicit equations with a named reservoir, derive what each predicts at the retained source, and find what would mimic or falsify each.
Goal
One deterministic calculation over 36 preregistered rows, with nine declared hypotheses and frozen adverse cases, giving quantitative conditional signatures and exact ordinary rivals. Any rejection or unresolved result is a valid outcome.
Virtual lab - simulated experiment
Proposed hypotheses, not results, photographs or hardware designs. No apparatus exists, and no mechanism here has been observed. Solid arrows are ordinary effects, dashed arrows are proposed effects, and lengths carry no measured value.
Start from what is ordinary
Ordinary recoil cares only about the state right now
Light carries momentum, so a source of light is pushed backwards. In the ordinary model, that push depends only on the current optical state, and stored momentum returns around any closed loop. Each proposal below breaks that picture in a different way, and each says how it could be shown wrong.
Three proposals, ranked by what a test would teach
C3 · Proposed
Holonomic loop: the order of steps matters
Proposes
A new term gives a force that depends on the order of two control steps, and sends its momentum to an unidentified reservoir.
Changes
Only the direction round a closed loop, with a matched optical state and dwell schedule. Claims that depend on heat stay unproved.
Predicts
Ordinary recoil gives the same mean both ways. The proposal gives opposite signs, and under the unproved premise P-theta, a phase left over after a closed loop.
Could be fooled by
A timing skew that follows path length gives the same force exactly. Hysteresis gives the same phase.
Fails if
The term proves to be a total derivative, or the order-odd force reads zero below a stated size.
Open caveat
Reservoir unidentified. P-theta unproved. Autonomous energy case unproved.
C1 · Proposed
Absorber handshake: emission depends on where the light will end up
Proposes
Emission changes in directions its light will never be absorbed, by more or less according to the sign of a coefficient, and the emitter responds before a distant shutter changes.
Changes
What the light will reach, with a half mask or an externally scheduled shutter.
Predicts
Steering across a half mask gives a signed power contrast where ordinary light gives none, and a step that leads the shutter by L/c.
Could be fooled by
Back-reflection, which arrives late. A ray that is absorbed later anyway gives an exact null.
Fails if
No step appears on an open path, on a static mask or a dynamic shutter. That rejects stated pairs of coefficients, not the idea outright.
Open caveat
Causal loops unresolved. The only constraint read is second-hand, and it gets no credit.
One vacuum reading of the programme's commutator: crossed channels convert to pseudoscalar quanta that leave the apparatus.
Changes
Polarisation and power, with the beam dumped on board. Without the dump the balance does not change.
Predicts
A residual and a box power deficit that grow as power squared, with crossed channels only.
Could be fooled by
Light leaking from the box gives the same tuple. Nonlinear loss can also depend on polarisation.
Fails if
No deficit or residual below a stated coupling, with leakage bounded.
Open caveat
A heuristic for one vacuum ansatz, with no exclusion credit. At the cited couplings, under their assumptions, it sits far below 1 pN. The top grid coupling reaches about 1 pN.
Conceptual schematic of proposed hypotheses, not results, not to scale. No apparatus exists. Teal lines are light, dashed purple marks a proposed effect, and red text names what would fool the test. Printed coefficients are declared values, not measurements. Inspect the retained model results.
Equivalent explanation: One emitter is shown under ordinary recoil, where the push depends only on the current optical state. In the holonomic loop, two paths visit the same states in opposite order, and the proposal gives them opposite forces, while ordinary recoil gives the same mean. In the absorber handshake, light steered across a half mask changes emitted power, and a shutter change would appear at the emitter early. In commutator quanta, crossed beams in a box with an on-board dump lose hidden quanta, with a residual growing as power squared. Each panel names its ordinary rival: timing skew, back-reflection, and leakage or nonlinear loss.
Virtual lab - simulated experiment
Layer one · Plain-language outcome
What this research slice found
The strongest result is three testable conditional signatures and the exact ordinary rivals that could mimic them. Nine hypotheses were supported as declared mathematics, which means the equations do what the protocol said. That is not physics being accepted, and no model passed a 1 pN test. The holonomic loop predicts a signed order-odd force, and a modulator skew that follows path length gives the same force exactly. The absorber handshake predicts a signed power contrast and an early onset, and a ray absorbed later gives an exact null. Commutator quanta, in one vacuum reading, sit far below 1 pN at the cited couplings on a heuristic, the top grid coupling reaches about 1 pN, and ordinary leakage gives the same tuple.
Virtual lab - simulated experiment
Layer two · What the evidence means
What the findings do and do not establish
These calculations support conditional equations, and nothing more. They are not observations, new laws, exclusions or instrument qualification. C3's reservoir is unidentified, its phase route needs the unproved premise P-theta, and its autonomous energy case is unproved. C1 has unresolved causal loops, and its second-hand constraint gets no credit. C2's numbers are a heuristic with no exclusion credit, and they test one vacuum ansatz only. No apparatus row has a finite measurement map, so 112 entries stay unproved and a benchmark score means nothing about a real instrument. An arbitrary source-fixed force can still mimic any finite table of forces, so each test narrows a stated class only.
Every value is an exact scalar from the one retained record. Predictions are conditional on the stated coupling, and each coupling is unknown. Native states are not acceptance states. Radians and dimensionless values appear as recorded. Benchmark scores use half-widths from another acquisition, so they qualify nothing. C3's contrast appears through its benchmark score, because the publication tool cannot address its channel names.
Signed predictions against an unknown coupling
What each proposal would predict, if its coupling were this size
Virtual lab - simulated experiment. These are calculated predictions, not observations. Each coupling is unknown, so no point here is a claimed value. Each chart has its own unit and one common scale, and bars left of the zero line are negative.
C3, holonomic loop. Loop phase under the unproved premise P-theta, rad, against Coefficient h.
C2 has no chart here. Its residual spans more than 30 decades on a heuristic with no exclusion credit, so a shared linear scale would show nothing. Its values are in the table below.
Retained facts, not physical measurements
Quantity
Recorded value
Evidence
H1, recovery at zero coupling, as declared mathematics
Attack C3 first: look for a primary bound on interferometer scale, which could confine it to a transverse form. This version's one primary is spent, so any changed mechanism needs a new version.
Layer three · Full technical record
Follow every fact to its retained source
The canonical research-slice envelope pins the exact retained bytes and fact locations. It does not assign a new scientific verdict or convert this study into tt.result.v1. Numeric pointers are provenance locations inside the JSON; the source files retain the original outcomes.
Non-JSON source downloads use a text suffix so browsers do not execute them. Schematics and prose are presentation context, not measured apparatus. Full source identities and frozen protocol amendments travel with the retained records.