Quaternion Pathfinder · PF-002-STATIONARITY-V1 research slice

Virtual lab - simulated experiment

Can a measurement design stay balanced as its sensors change?

Do alternation orders or a pilot force let simulated sensors meet a predeclared 1 pN margin while their gains change over time?

Reviewed research publication. This is not a physical measurement or a canonical technology-acceptance result.

In plain English

Understanding this experiment

What is being measured?
A simulated light source switches between two phase settings. Two simulated force sensors are subtracted while their gains change over time, through slow drift, small steps, changes that line up with the phase switching, and changes inside a single measurement window. Four designs are compared: random pairs, two alternation orders, and an order with an assumed separate pilot force whose readings track the gain ratio. No physical force was measured.
Why does it matter?
Light carries momentum, so a source of light feels a tiny backwards push: ordinary radiation recoil. Pathfinder research needs to measure a force that small honestly, because any later claim about a hypothetical engine would first have to be separated from this known effect. This slice tests that measurement only. It does not test the hypothetical engine mechanism. An earlier slice found that changes in sensor balance can turn a large shared disturbance into a false signal. A failed simulated criterion identifies a limit of this design and this conservative test, not of every possible design.
How does the title relate?
Stationarity means staying the same over time. This PF-002 slice asks whether measurement designs can tolerate sensors that do not stay the same, whether they drift slowly or step. It tests an instrument, not a new propulsion mechanism.

Setup, objective and goal

How the experiment works

Objective
Find which of four designs best resists change in sensor gain over time, and whether an assumed pilot force certifies the 1 pN requirement at the primary level.
Goal
Test a predeclared margin with model-derived bounds, adverse controls and 16 fresh simulated seeds, and keep every failure, refusal and changed preregistration visible.

Virtual lab - simulated experiment

Conceptual gain profiles and acquisition designs, not measured traces or built apparatus. Curve heights and time spacing have no numerical scale. P is the primary sensor and R the reference.

The source switches. The sensors do not stand still.

Slow drift: an illustrative permitted gain patternA gradual change can be suppressed by a suitable alternation order. That does not remove every kind of change. This is a conceptual profile, not a recorded time series. The horizontal direction is time; curve heights are not measurements.GainTime →

Slow drift

A gradual change can be suppressed by a suitable alternation order. That does not remove every kind of change.

Change that follows the labels: an illustrative permitted gain patternIf gain changes with the phase labels, it can carry the same pattern as the wanted signal. This is a conceptual profile, not a recorded time series. The horizontal direction is time; curve heights are not measurements.ABABABGainTime →

Change that follows the labels

If gain changes with the phase labels, it can carry the same pattern as the wanted signal.

Change inside a dwell: an illustrative permitted gain patternA gain change inside one measurement window defeats the assumption that each reading has one stable gain. This is a conceptual profile, not a recorded time series. The horizontal direction is time; curve heights are not measurements.One dwellGainTime →

Change inside a dwell

A gain change inside one measurement window defeats the assumption that each reading has one stable gain.

Illustrative schematic of allowed changes, not exhaustive profiles or observed data. A/B marks illustrate phase labels; the dashed box marks one conceptual dwell. The study also includes steps and adverse controls. Inspect the retained gain model and outcomes.

Four acquisition designs

Change the order, or add information?

A0 · Random pairsA0: Random pairsPair the phase settings in random order. This is the retained comparison design, not a guarantee against drift. Schematic only. Solid lines connect readings; dashed lines identify added calibration or witness information; dotted lines in the null design identify commands based only on earlier readings. Any A/B tiles are illustrative, not a full registered switching sequence.PREstimatePaired source settingsA/BB/A

Random pairs

Pair the phase settings in random order. This is the retained comparison design, not a guarantee against drift.

A1 · Balance the orderA1: Balance the orderUse the eight-dwell Thue-Morse order to cancel slow trends in the bound. Faster or label-following changes still need their own allowance. Schematic only. Solid lines connect readings; dashed lines identify added calibration or witness information; dotted lines in the null design identify commands based only on earlier readings. Any A/B tiles are illustrative, not a full registered switching sequence.PREstimateBalanced alternationABBA

Balance the order

Use the eight-dwell Thue-Morse order to cancel slow trends in the bound. Faster or label-following changes still need their own allowance.

A2 · Switch fasterA2: Switch fasterUse a sixteen-dwell order. The detector exposure mapping is assumed, not reference-derived; its apparent advantage is conditional. Schematic only. Solid lines connect readings; dashed lines identify added calibration or witness information; dotted lines in the null design identify commands based only on earlier readings. Any A/B tiles are illustrative, not a full registered switching sequence.PREstimateFaster alternationABBABAAB

Switch faster

Use a sixteen-dwell order. The detector exposure mapping is assumed, not reference-derived; its apparent advantage is conditional.

A3 · Track with a pilotA3: Track with a pilotApply an assumed separate pilot force to both sensors. Their ratio adjusts the subtraction weight in the calculation only. Nothing is fed back to the apparatus. Schematic only. Solid lines connect readings; dashed lines identify added calibration or witness information; dotted lines in the null design identify commands based only on earlier readings. Any A/B tiles are illustrative, not a full registered switching sequence.PREstimateSeparate assumed pilot pathRatio changes the estimate only

Track with a pilot

Apply an assumed separate pilot force to both sensors. Their ratio adjusts the subtraction weight in the calculation only. Nothing is fed back to the apparatus.

Conceptual schematic of model information paths, not measured performance or hardware designs. A/B tiles illustrate settings, not actual order; force inputs and full timing are in the technical schematic. Follow the retained comparison and controls.
Inspect the full technical signal-flow schematic
PF-002 stationarity study version 1: setup, mechanism, objective and goal Conceptual schematic of a simulated experiment, not to scale. A simulated optical source alternates two phase labels in a chosen order. Its force reaches a primary channel and leaks into a reference channel, and both feel a shared disturbance, while each channel's gain changes over time. Readings from both channels enter a weighted difference, which gives a contrast with a half-width, compared with a detector prediction. Only in design A3, an assumed separate periodic calibration force enters both channels, and a ratio computed from their readings scales the weight during estimation. That ratio goes only into the calculation and there is no feedback to the apparatus. Four designs are compared: random pairs, an eight-dwell Thue-Morse order, a sixteen-dwell faster order, and the eight-dwell order with the pilot. Controls include no force, phase null, a laboratory-fixed force, source-fixed impostors with and without lag, a reference-path mimic and a large out-of-window force. The goal is a predeclared 1 piconewton margin, and failures stay visible. Can a measurement design stay balanced as its sensors change? Virtual lab - simulated experiment. Conceptual schematic, not to scale; no measured calibration. Objective: find which design best resists gain change. Goal: a predeclared 1 pN margin at each declared level, with controls and truth audits. Assumed pilot, A3 only separate periodic force, 0.5 Hz, 1 nN Optical source phase labels A and B order is the design choice 80 s total, 40 s per label Primary force channel first-order response gain changes over time Reference force channel a different response gain changes over time force leakage Shared disturbance common force and heat Weighted difference B-minus-A contrast with one half-width gain mismatch leaks here Pilot ratio, A3 only primary over reference read from both channels scales the weight, in calculation only Comparison detector-based prediction 1 pN goal Four designs, matched in time and exposure A0 random pairs A B B A A B A B the retained comparator A1 Thue-Morse 8 A B B A B A A B order cancels slow trends A2 Thue-Morse 16 ABBABAABBAABABBA 5 s dwells; exposure assumed A3 A1 plus pilot adds the assumed pilot paths above ratio read in a 2 s window Controls that must behave as declared No force | phase null | laboratory-fixed force | source-fixed impostors, instant and lagged | reference-path mimic | large out-of-window force A source-fixed instant force reverses with the source exactly as recoil does, so this model cannot separate them. Reading the lines model force or readings reference leakage assumed pilot force, A3 only ratio in estimation, A3 No line returns to the apparatus: the ratio only enters the calculation. Boxes are model parts, not hardware. Label positions, sizes and spacing carry no measured value.
Conceptual schematic, not to scale. Solid lines show model forces and readings, the dashed line is reference leakage, the dotted lines are the assumed pilot force in design A3 only, and the dash-dot lines show its ratio entering the estimate. No line returns to the apparatus. Boxes are model parts, not hardware, and positions carry no measured value. Inspect the retained model results.

Equivalent explanation: A simulated source alternates phase labels in an order that is the design choice. Its force reaches a primary sensor and leaks into a reference sensor, and both also feel a shared force and heat. Each sensor's gain changes over time. Their readings enter a weighted difference, which gives a contrast with one half-width, compared with a detector-based prediction. A0 uses random pairs, A1 an eight-dwell Thue-Morse order that cancels slow trends, and A2 a faster sixteen-dwell order under an assumed exposure model. A3 uses the eight-dwell order and adds an assumed separate periodic 1 nN calibration force into both sensors. A ratio computed from the two sensors' readings then scales the weight during estimation. That ratio only enters the calculation: nothing is fed back to the apparatus. Controls include no force, a phase null, a laboratory-fixed force, source-fixed impostors, a reference-path mimic and a large out-of-window force. A source-fixed instant force reverses with the source exactly as recoil does, so this model cannot separate them.

Virtual lab - simulated experiment

Layer one · Plain-language outcome

What this research slice found

The pilot force helped against one modelled leakage but did not certify the primary 1 pN criterion. The worst-case control margin stayed negative, so H1 is certification_not_met. No pilot row certified. Fourteen of the 46 configurations cleared the criterion conditionally, all without the pilot, and only in constant, blind-coupling, common-force or low-rate scenarios. Twenty-one passed their seeds without certifying, eight were negative, and three could not be judged. Those failures stand. This is not a working engine, and it is not a no-go result either: a failed conservative bound does not show that a design cannot reach 1 pN.

Virtual lab - simulated experiment

Layer two · What the evidence means

What the findings do and do not establish

The pilot removes the label-synchronous gain term it can track, but its short window adds noise, normalisation and mixing terms, and the bound's net benefit test, H5, was refuted. Alternation orders reduce slow drift in the bound. None of the four designs was certified in the scenario where gain changes inside a measurement window. Those outcomes differ: adverse witnesses gave a scoped failure for A0 and A1, A2 was negative with a certification gap, and A3 stayed inconclusive because its large-force audit refused. This says nothing about every realisation of that scenario or about other technology. Controls failed in some difficult scenarios: laboratory-fixed detection and force-free rejection missed in finite seeds, and those rows stay visible. Rank four of five and the instant source-fixed ambiguity are properties of the model's structure. They are not an empirical proof of attribution either way, and more seeds would not resolve them. H7 is a statement about a bound that no admissible witness attained. Sixteen seeds are finite evidence and prove no bound on a whole nuisance class. Model-derived calculations, finite seed evidence, unproved premises and physical validation are different things, and physical validation is absent.

A margin is the separation left after the model's error allowance. The requirement is 1 pN, and a piconewton (pN) is one trillionth of a newton. These are native study outcomes, not tt.result.v1 acceptance states. stationarity_margin_positive_conditional means the row cleared every condition, conditional on the stated premises. seeded_pass_not_robust means simulated seeds matched but the bound did not certify. negative means a control or criterion failed. inconclusive_invalid_envelope means the row could not be judged. Hypotheses read as supported, refuted or inconclusive by their predeclared tests. Force values are rounded to two decimal places; downloads keep full precision.

Selected retained margins

The pilot's primary margins did not certify

Virtual lab - simulated experiment. S05 is the retained label-following gain scenario. A3 with the retained pilot setting only. These two values do not compare all four acquisition designs.

A3 pilot at S05Control margin
-3.35 pN
A3 pilot at S05Signal margin
0.23 pN
The vertical line is zero, not the study's 1 pN requirement. Negative values extend left; positive values extend right on one shared linear scale. Hatched bars are control margins; solid bars are signal margins. Exact retained values set the lengths, and labels round to two decimals. Positive alone does not mean certified: the predeclared requirement and all controls still apply. Full values and pointers remain in the table below.
Retained facts, not physical measurements
QuantityRecorded valueEvidence
H1, the primary criterioncertification_not_metOriginal record
/hypotheses/H1/status
H1 evidence statecertification_gapOriginal record
/hypotheses/H1/evidence
A3 S05 at 1 nN: worst-case control margin-3.35 pNOriginal record
/outcomes/A3-thue-morse-8-pilot|S05-label-retained|0/design/m_null_newtons
A3 S05 at 1 nN: worst-case signal margin0.23 pNOriginal record
/outcomes/A3-thue-morse-8-pilot|S05-label-retained|0/design/m_signal_newtons
Original exploratory at revision 8: H1certification_not_metOriginal record
/hypotheses/H1/status
H2, order against random pairsinconclusiveOriginal record
/hypotheses/H2
H3, drift reductionsupportedOriginal record
/hypotheses/H3
H4, rate term of faster alternationsupportedOriginal record
/hypotheses/H4
H5, pilot net benefit in the boundrefutedOriginal record
/hypotheses/H5
H6, pilot dose scalingsupportedOriginal record
/hypotheses/H6
H8, blind term not reducedsupportedOriginal record
/hypotheses/H8
H9, instant impostorinconclusiveOriginal record
/hypotheses/H9
H11, within-window gaininconclusiveOriginal record
/hypotheses/H11
H7, candidate level, bound onlysupportedOriginal record
/hypotheses/H7/status
H7 attained by an admissible witnessfalseOriginal record
/hypotheses/H7/attained_by_witness
H10, lag attributionrank_raised_not_resolvedOriginal record
/hypotheses/H10/status
A3 numeric rank of five amplitude columns4Original record
/rank/A3-thue-morse-8-pilot/numeric_rank
A2 S11: lab-fixed forces detected, of 160Original record
/outcomes/A2-thue-morse-16-fast|S11-label-within-window|0/lab_detection/detected
A0 random pairs, constantstationarity_margin_positive_conditionalOriginal record
/outcomes/A0-retained-random-pairs|S01-constant|0/outcome
A0 random pairs, slow driftseeded_pass_not_robustOriginal record
/outcomes/A0-retained-random-pairs|S02-drift-retained|0/outcome
A0 random pairs, rate, retained levelnegativeOriginal record
/outcomes/A0-retained-random-pairs|S03-rate-retained|0/outcome
A0 random pairs, rate, candidate levelseeded_pass_not_robustOriginal record
/outcomes/A0-retained-random-pairs|S04-rate-candidate|0/outcome
A0 random pairs, label gain, retained levelinconclusive_invalid_envelopeOriginal record
/outcomes/A0-retained-random-pairs|S05-label-retained|0/outcome
A0 random pairs, label gain, candidate levelseeded_pass_not_robustOriginal record
/outcomes/A0-retained-random-pairs|S06-label-candidate|0/outcome
A0 random pairs, blind coupling, monitored levelstationarity_margin_positive_conditionalOriginal record
/outcomes/A0-retained-random-pairs|S07-blind-monitored|0/outcome
A0 random pairs, blind coupling, candidate levelstationarity_margin_positive_conditionalOriginal record
/outcomes/A0-retained-random-pairs|S08-blind-candidate|0/outcome
A0 random pairs, common forcestationarity_margin_positive_conditionalOriginal record
/outcomes/A0-retained-random-pairs|S09-common-force|0/outcome
A0 random pairs, combinedseeded_pass_not_robustOriginal record
/outcomes/A0-retained-random-pairs|S10-combined-candidate|0/outcome
A0 random pairs, gain inside the windownegativeOriginal record
/outcomes/A0-retained-random-pairs|S11-label-within-window|0/outcome
A1 Thue-Morse 8, constantstationarity_margin_positive_conditionalOriginal record
/outcomes/A1-thue-morse-8|S01-constant|0/outcome
A1 Thue-Morse 8, slow driftseeded_pass_not_robustOriginal record
/outcomes/A1-thue-morse-8|S02-drift-retained|0/outcome
A1 Thue-Morse 8, rate, retained levelnegativeOriginal record
/outcomes/A1-thue-morse-8|S03-rate-retained|0/outcome
A1 Thue-Morse 8, rate, candidate levelstationarity_margin_positive_conditionalOriginal record
/outcomes/A1-thue-morse-8|S04-rate-candidate|0/outcome
A1 Thue-Morse 8, label gain, retained levelnegativeOriginal record
/outcomes/A1-thue-morse-8|S05-label-retained|0/outcome
A1 Thue-Morse 8, label gain, candidate levelseeded_pass_not_robustOriginal record
/outcomes/A1-thue-morse-8|S06-label-candidate|0/outcome
A1 Thue-Morse 8, blind coupling, monitored levelstationarity_margin_positive_conditionalOriginal record
/outcomes/A1-thue-morse-8|S07-blind-monitored|0/outcome
A1 Thue-Morse 8, blind coupling, candidate levelstationarity_margin_positive_conditionalOriginal record
/outcomes/A1-thue-morse-8|S08-blind-candidate|0/outcome
A1 Thue-Morse 8, common forcestationarity_margin_positive_conditionalOriginal record
/outcomes/A1-thue-morse-8|S09-common-force|0/outcome
A1 Thue-Morse 8, combinedseeded_pass_not_robustOriginal record
/outcomes/A1-thue-morse-8|S10-combined-candidate|0/outcome
A1 Thue-Morse 8, gain inside the windownegativeOriginal record
/outcomes/A1-thue-morse-8|S11-label-within-window|0/outcome
A2 Thue-Morse 16, constantstationarity_margin_positive_conditionalOriginal record
/outcomes/A2-thue-morse-16-fast|S01-constant|0/outcome
A2 Thue-Morse 16, slow driftseeded_pass_not_robustOriginal record
/outcomes/A2-thue-morse-16-fast|S02-drift-retained|0/outcome
A2 Thue-Morse 16, rate, retained levelseeded_pass_not_robustOriginal record
/outcomes/A2-thue-morse-16-fast|S03-rate-retained|0/outcome
A2 Thue-Morse 16, rate, candidate levelstationarity_margin_positive_conditionalOriginal record
/outcomes/A2-thue-morse-16-fast|S04-rate-candidate|0/outcome
A2 Thue-Morse 16, label gain, retained levelinconclusive_invalid_envelopeOriginal record
/outcomes/A2-thue-morse-16-fast|S05-label-retained|0/outcome
A2 Thue-Morse 16, label gain, candidate levelseeded_pass_not_robustOriginal record
/outcomes/A2-thue-morse-16-fast|S06-label-candidate|0/outcome
A2 Thue-Morse 16, blind coupling, monitored levelstationarity_margin_positive_conditionalOriginal record
/outcomes/A2-thue-morse-16-fast|S07-blind-monitored|0/outcome
A2 Thue-Morse 16, blind coupling, candidate levelstationarity_margin_positive_conditionalOriginal record
/outcomes/A2-thue-morse-16-fast|S08-blind-candidate|0/outcome
A2 Thue-Morse 16, common forcestationarity_margin_positive_conditionalOriginal record
/outcomes/A2-thue-morse-16-fast|S09-common-force|0/outcome
A2 Thue-Morse 16, combinedseeded_pass_not_robustOriginal record
/outcomes/A2-thue-morse-16-fast|S10-combined-candidate|0/outcome
A2 Thue-Morse 16, gain inside the windownegativeOriginal record
/outcomes/A2-thue-morse-16-fast|S11-label-within-window|0/outcome
A3 pilot, constantseeded_pass_not_robustOriginal record
/outcomes/A3-thue-morse-8-pilot|S01-constant|0/outcome
A3 pilot, slow driftnegativeOriginal record
/outcomes/A3-thue-morse-8-pilot|S02-drift-retained|0/outcome
A3 pilot, rate, retained levelnegativeOriginal record
/outcomes/A3-thue-morse-8-pilot|S03-rate-retained|0/outcome
A3 pilot, rate, candidate levelseeded_pass_not_robustOriginal record
/outcomes/A3-thue-morse-8-pilot|S04-rate-candidate|0/outcome
A3 pilot, label gain, retained levelseeded_pass_not_robustOriginal record
/outcomes/A3-thue-morse-8-pilot|S05-label-retained|0/outcome
A3 pilot, label gain, retained level, dose row 0.5 nNseeded_pass_not_robustOriginal record
/outcomes/A3-thue-morse-8-pilot|S05-label-retained|1/outcome
A3 pilot, label gain, retained level, dose row 2 nNseeded_pass_not_robustOriginal record
/outcomes/A3-thue-morse-8-pilot|S05-label-retained|2/outcome
A3 pilot, label gain, candidate levelseeded_pass_not_robustOriginal record
/outcomes/A3-thue-morse-8-pilot|S06-label-candidate|0/outcome
A3 pilot, blind coupling, monitored levelseeded_pass_not_robustOriginal record
/outcomes/A3-thue-morse-8-pilot|S07-blind-monitored|0/outcome
A3 pilot, blind coupling, candidate levelseeded_pass_not_robustOriginal record
/outcomes/A3-thue-morse-8-pilot|S08-blind-candidate|0/outcome
A3 pilot, common forceseeded_pass_not_robustOriginal record
/outcomes/A3-thue-morse-8-pilot|S09-common-force|0/outcome
A3 pilot, combinedseeded_pass_not_robustOriginal record
/outcomes/A3-thue-morse-8-pilot|S10-combined-candidate|0/outcome
A3 pilot, gain inside the windowinconclusive_invalid_envelopeOriginal record
/outcomes/A3-thue-morse-8-pilot|S11-label-within-window|0/outcome

What comes next?

Treat this version as closed. Any new design needs a new frozen protocol. The most informative route is to bound the reference channel's gain directly, because that term now sets the half-width in most configurations.

Layer three · Full technical record

Follow every fact to its retained source

The canonical research-slice envelope pins the exact retained bytes and fact locations. It does not assign a new scientific verdict or convert this study into tt.result.v1. Numeric pointers are provenance locations inside the JSON; the source files retain the original outcomes.

Download the content-addressed publication envelope

sha256:9d3d5ab018026b8cd5a87fb4d36b375f40cb7a6fea4513682c49ad5990a933ab

Non-JSON source downloads use a text suffix so browsers do not execute them. Schematics and prose are presentation context, not measured apparatus. Full source identities and frozen protocol amendments travel with the retained records.